High-Precision Peristaltic Pump. Multi-channel Pump. High IP Grade Peristaltic Pump.
Intergrated into system for liquid dosing/dispensing/vending/filling. Compact Size.
Intelligent liquid dispensing filling system. Vaccine, pharmaceutical reagents filling.
Handle water sampling pump. Semi-automatic liquid filling machine.
High-accuracy infusion syringe pump. Microfluid injection.
GP3000FC Smart micro gear peristaltic pump
Provide peristaltic pump tubing options, such as platinum vulcanized silicone hose, the hose for cell research, etc.
What Is Radiofrequency Ablation?
Radiofrequency ablation refers to the use of radiofrequency waves to heat the tumor tissue to 95°C under the guidance of images (CT, color ultrasound), and to accurately insert the ablation electrode into the tumor site through percutaneous puncture, so that the tumor tissue produces local high temperature and complete necrosis, thereby achieving the purpose of treating the tumor. At present, this technology has been widely used in various solid tumors, especially for liver tumors, and has almost become the preferred standard treatment. It has the advantages of less trauma, a high cure rate, low cost and few complications.
How Does a Radiofrequency Ablation System Work?
A radiofrequency ablation system generally includes a radiofrequency generator, ablation electrodes and skin electrode, which together with human tissue form a complete circuit. The electrode needle is directly inserted into the diseased tissue of the human body, and the radiofrequency generator generates high-frequency alternating current (common frequency is 200kHz~500kHz). The current enters the surrounding tissue from the exposed part of the end of the electrode needle, causing the polar molecules and ions in the tissue around the electrode needle to vibrate and rub, and then convert into heat energy. As the operation continues, the heat energy gradually conducts to the periphery, which can make the temperature in the tissue exceed 60°C, causing irreversible thermal coagulation, degeneration and necrosis of the diseased tissue, thus achieving the purpose of treatment.
In conventional radiofrequency ablation, as the electrode temperature rises, local high temperature will occur, forming thrombus, eschar and carbonization on the electrode surface, which will affect the energy output and ablation effect. Therefore, a cold electrode radiofrequency ablation system can be used to improve the ablation efficiency and the success rate of the operation. The system uses an electrode needle with an internal tube and continuously pumps cold saline into the electrode needle through a cold circulation pump. The internal tube electrode needle has two types: closed and open.
Cooling Pump for Radiofrequency Ablation - Chonry UCP328 OEM Peristaltic Pump
Precisely liquid Control and high pressures are essential for overall system performance. The cooled pump in RF ablation system is often chosen for this job is a peristaltic pump. It is a type of positive displacement pump. Peristaltic pumps work by using a flexible tube that is squeezed by a series of rollers or shoes. The rollers move along the length of the tube, compressing it and creating a series of sealed pockets. As the rollers move, the pockets of fluid are forced through the tube and out of the pump.
Chonry UCP328 OEM peristaltic pump is specially designed for RF ablation system devices. The max pressure is up to 6 bar (87psi) and the flow rate is 350ml/min. Chonry RF ablation cooling pumps are often integrated into medical devices to flush and cool catheters.
Advantages of RF Ablation System OEM Cooling Peristaltic Pump
- High reliability, ease of operation and simple integration.
- Low noise levels and precise control.
- Good mechanical compatibility
- Provide continuous liquid flow, high reliability.
- UCP328 peristaltic pump OEM is often used as the irrigation pump sucks the saline solution and conveys it into the catheter.
Baoding Chuangrui Precision Pump Co., Ltd. is located in Hebei of China. Started production of the peristaltic pump in 2010, as the top pump manufacturer in China, we now have 30 series production including peristaltic metering pump, pump head, dispensing filling system, micro gear pumps and industrial peristaltic pumps.